Integrated High-Capacity Waste Treatment
Is the Mark VII-N Right for Your Facility?
The San-I-Pak Mark VII-N is designed for facilities that need a modular, integrated onsite treatment system with higher processing capacity, hands-off loading, and built-in waste compaction.
Its three-position process—load, sterilize, and dump—supports a controlled workflow from collection through final compaction. With a listed processing capacity of 400 pounds per hour, the Mark VII-N is suited to facilities managing larger volumes of regulated medical waste.
The system is available in left-hand and right-hand configurations, allowing the equipment orientation to better accommodate the facility’s available space and operational layout.
The Mark VII-N integrates waste loading, steam sterilization, discharge, and compaction within one coordinated footprint.
An integrated cart dumper supports hands-off loading, while the system’s high-density compactor reduces the volume of treated waste. The Mark VII-N can manage regulated medical waste and municipal solid waste within the same system footprint.
The unit can be installed either indoors or outdoors and is available in left-hand or right-hand equipment orientations.
Sterilizer process
Three position: load, sterilize, dump
Chamber size
38″ inside diameter × 55″ long
Capacity
400 lbs. per hour
Load time
3–4 minutes per chamber
Cycle time
45 minutes
10-hour shift capacity
4,000 lbs.
16-hour shift capacity
6,400 lbs.
24-hour shift capacity
9,600 lbs.
Compaction ratio
4:1
Compatible carts
64- or 96-gallon trainable Toter carts
- Three-position sterilizer: load, sterilize, and dump
- Modular, integrated sterilizer and compactor
- Cart dumper for hands-off loading
- High-density compactor
- 4:1 compaction ratio
- Manages RMW and MSW within one footprint
- Compatible with 64- and 96-gallon trainable Toter carts
- San-I-Pak Net™ for downloading cycle records
- Remote troubleshooting
- Software updates and alarm messaging
- Sterilization cycle operating at 284°F for 35 minutes
- Self-Contained, L, and XL compactor options
- Indoor or outdoor installation
Electrical
- 480V / 40A / 3-phase, or
- 208V / 70A / 3-phase
- 120V / 40A / single-phase
Steam
- 65–90 PSI
- 125 lbs./hour per chamber
Water
- Accessible water supply
- 30–60 PSI
Drainage
- Sanitary drain
The unit may also be installed indoors or outdoors, depending on the site layout and utility access.
Explore The Mark Series